MELSOFT Library

Cam output control FB library

The operation of the provided FB in your device is not guaranteed. Use the FB according to the specifications of your device after checking the assignment of devices and parameters.

Applicable model FX5U(C)
Name Version Size (byte) Last update File for download note
Cam output control FB library 1.00A 12,968,151 Jan. 18, 2019 fb-camctr_f.zip GX Works3
Relevant manual Type Language
SH-082059-A MELSEC iQ-F Cam Output Control Function Block Reference Japanese
SH-082060ENG-A English
SH-082061CHN-A Chinese (simplified)
FB name Function name Description Ver.
M+CamCtr_CamOutputTable_F Cam output table setting Sets the angle for the ON/OFF control of the cam output. 00
M+CamCtr_AngleAdvFunc_F Automatic advance function setting Sets the automatic advance function. 00
M+CamCtr_CamOutput_F Cam output Turns on and off the cam output according to the input angle (count value). 00


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works3 of the following version has been installed.

  1. GX Works3: Version 1.050C or later


[How to use MELSOFT Library]

  1. Select [Library Operation] - [Register to Library List] - [Library] from the [Project] menu.
  2. In the [Register Library to Library List] dialog box, select the installed library and click the [Open] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.