MELSOFT Library

FB library for the NZ2GF2S-60IOLD8 (MELSEC-Q/L compatible)

This FB library is for CC-Link IE field network remote IO-Link module.

Applicable model NZ2GF2S-60IOLD8
Name Version Size (byte) Last update File for download
NZ2GF2S-60IOLD8 function block (Japanese) 1.10L 3,521,831 Oct. 31, 2018 fb-nz2gf2s-60iold8_v110l_j.zip
NZ2GF2S-60IOLD8 function block (English) 1.10L 3,406,621 Oct. 31, 2018 fb-nz2gf2s-60iold8_v110l_e.zip
Relevant manual Type Language
FBM-M233-A CC-Link IE Field Network Remote IO-Link Module Function Block Reference (For MELSEC-Q/L) Japanese
FBM-M234-A English
FB name Function name Description Ver.
M+NZ2GF2S-60IOLD8_RemoteBufMemRd Remote buffer memory read Reads the value from the specified remote buffer memory. 1.00A
M+NZ2GF2S-60IOLD8_RemoteBufMemWt Remote buffer memory write Writes the value to the specified remote buffer memory. 1.00A
M+NZ2GF2S-60IOLD8_OutputOnCntRd Number of ON times integration value read Reads the number of output ON times integration value of the IO-Link module. 1.00A
M+NZ2GF2S-60IOLD8_OutputOnCntClr The number of output ON times integration value clear Clears the number of output ON times integration value of the IO-Link module. 1.00A
M+NZ2GF2S-60IOLD8_UnitParamRd Parameter Read Reads the IO-Link module parameters. 1.00A
M+NZ2GF2S-60IOLD8_UnitParamWt Parameter Write Writes the IO-Link module parameters. 1.00A
M+NZ2GF2S-60IOLD8_DeviceParamRd IO-Link Device Parameter Read Reads the specified parameter from the IO-Link device. 1.00A
M+NZ2GF2S-60IOLD8_DeviceParamWt IO-Link Device Parameter Write Writes the specified parameter to the IO-Link device. 1.00A
M+NZ2GF2S-60IOLD8_DeviceChg Device Change Turns on the device change flag and disables the detection ofdisconnection error.
This module FB disables input/output in IO-Link mode and turns off input/output in SIO mode.
This module FB is used when the device is replaced during power-on.
1.00A
M+NZ2GF2S-60IOLD8_EventRd Event read Reads the oldest event information from unchecked events. 1.00A
M+NZ2GF2S-60IOLD8_EventClr Event History clear Clears the event history. 1.00A


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (Japanese): Version 1.580E or later
  2. GX Works2 (English): Version 1.580E or later


[Installation method]

  1. Execute setup.exe in the fb-nz2gf2s-60iold8_v110l_j folder or fb-nz2gf2s-60iold8_v110l_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.