MELSOFT Library

FB library for the NZ2GF2S-60IOLD8 (MELSEC iQ-R compatible)

This FB library is for CC-Link IE field network remote IO-Link module.

Applicable model NZ2GF2S-60IOLD8
Name Version Size (byte) Last update File for download
CC-Link IE field network remote IO-Link module function block 1.00C 1,055,834 Oct. 31, 2018 fb-nz2gf2s-60iold8_r.zip
Relevant manual Type Language
BCN-P5999-1047-A CC-Link IE Field Network Remote IO-Link Module Function Block Reference (For MELSEC iQ-R) Japanese
BCN-P5999-1048-A English
FB name Function name Description Ver.
M+NZ2GF2S-60IOLD8_RemoteBufMemRd Remote buffer memory read Reads the value from the specified remote buffer memory. 1.00C
M+NZ2GF2S-60IOLD8_RemoteBufMemWt Remote buffer memory write Writes the value to the specified remote buffer memory. 1.00C
M+NZ2GF2S-60IOLD8_OutputOnCntRd Number of output ON times integration value read Reads the number of output ON times integration value of the IO-Link module. 1.00C
M+NZ2GF2S-60IOLD8_OutputOnCntClr Number of output ON times integration value clear Clears the number of output ON times integration value of the IO-Link module. 1.00C
M+NZ2GF2S-60IOLD8_UnitParamRd Parameter read Reads the IO-Link module parameters. 1.00C
M+NZ2GF2S-60IOLD8_UnitParamWt Parameter write Writes the IO-Link module parameters. 1.00C
M+NZ2GF2S-60IOLD8_DeviceParamRd IO-Link device parameter read Reads the specified parameter from the IO-Link device. 1.00C
M+NZ2GF2S-60IOLD8_DeviceParamWt IO-Link device parameter write Writes the specified parameter to the IO-Link device. 1.00C
M+NZ2GF2S-60IOLD8_DeviceChg Device change Turns on the device change flag and disables the detection of disconnection error.
This module FB disables input/output in IO-Link mode and turns off input/output in SIO mode.
This module FB is used when the device is replaced during power-on.
1.00C
M+NZ2GF2S-60IOLD8_EventRd Event read Reads the oldest event information from unchecked events. 1.00C
M+NZ2GF2S-60IOLD8_EventClr Event history clear Clears the event history. 1.00C


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works3 of the following version has been installed.

  1. GX Works3: Version 1.050C or later


[How to use MELSOFT Library]

  1. Select [Library Operation] - [Register to Library List] - [Library] from the [Project] menu.
  2. In the [Register Library to Library List] dialog box, select the installed library and click the [Open] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.