MELSOFT Library

FB for the analog-digital converter module (other languages)

This FB library is for the MELSEC-L analog-digital converter module.

Applicable model L60ADVL8, L60ADIL8
File name Size Last update Version
fb-l60adl8_v110l_e.zip 3,906,613 bytes Sep. 25, 2015 1.10L
Relevant manual Type Language
FBM-M117-B MELSEC-L Analog-Digital Converter Module FB Library Reference Manual English
FBM-M144-A Chinese (simplified)
FB name Function name Description Ver.
M+L60ADL8_ReadADVal Read A/D conversion data Reads the A/D conversion data of a specified channel. 1.00A
M+L60ADL8_ReadAllADVal Read all A/D conversion data Reads the A/D conversion data of all channels. 1.00A
M+L60ADL8_ReadScalingVal Read scaling value Reads the scaling value of a specified channel. 1.00A
M+L60ADL8_ReadAllScalingVal Read all scaling values Reads the scaling values of all channels. 1.00A
M+L60ADL8_SetADConversion Enable/disable A/D conversion Enables or disables the A/D conversion for a specified channel or all channels. 1.00A
M+L60ADL8_SetAverage Averaging process setting Configures a specified channel for the Averaging processing A/D conversion method. 1.00A
M+L60ADL8_SetScaling Scaling setting Configures a specified channel's scaling value output settings. 1.00A
M+L60ADL8_SetProcessAlarm Process alarm setting Configures a specified channel's process alarm settings. 1.00A
M+L60ADL8_SetInputSignalErr Input signal error detection setting Configures a specified channel's input signal error detection settings. 1.00A
M+L60ADL8_SetInputSignalErrExp Input signal error detection extension setting Sets the input signal error detection extension setting of a specified channel. 1.00A
M+L60ADL8_RequestSetting Operation condition setting request Applies changes made to each function's operational condition settings. 1.00A
M+L60ADL8_SetOffsetVal Offset setting Sets the offset value of a specified channel to the current analog value. 1.00A
M+L60ADL8_SetGainVal Gain setting Sets the gain value of a specified channel to the current analog value. 1.00A
M+L60ADL8_ErrorOperation Error operation Performs monitoring and reset of intelligent function module error codes. 1.00A
M+L60ADL8_OGBackup Offset/gain value save Reads the offset/gain setting values of the user range and save them to a file. 1.00A
M+L60ADL8_OGRestore Offset/gain value restore Restores the offset/gain setting values of the user range setting that are saved in a file to the module. 1.00A
M+L60ADL8_ShiftOperation Shift operation Adds the shift amount to the digital value. 1.00A
M+L60ADL8_DiffOperation Differential conversion process Outputs the difference obtained by subtracting the standard value from the digital value. 1.00A
M+L60ADL8_DigitalClipOperation Digital clipping operation Limits a digital value at the digital clipping upper and lower limit values. 1.00A


[Improvement history of the FB for the analog-digital converter module from Ver.1.00A to Ver.1.10L (Sep., 2015)]

No. Description
1 The applicable version of GX Works2 has been added.
・This FB can be installed to GX Works2 of any language version.


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (English): Version 1.24A or later
  2. GX Works2 (Chinese (simplified)): Version 1.49B or later
  3. GX Works2 (Chinese (traditional)): Version 1.49B or later
  4. GX Works2 (Korean): Version 1.49B or later


[How to extract the compressed file]

Copy the file to a folder.
After the copied file is decompressed, the fb-l60adl8_v110l_e folder is created.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Installation method]

  1. Execute setup.exe in the fb-l60adl8_v110l_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.