MELSOFT Library

FB library for the CC-Link IE Field Network waterproof type remote IO-Link module (For MELSEC-Q/L Series)

This FB library is for the CC-Link IE Field Network waterproof type remote IO-Link module.

Applicable model NZ2GF12A-60IOLH8
File name Size Last update Version
fb-nz2gf12a-60iolh8_v100a_e.zip 3,428,058 bytes Apr. 27, 2018 1.00A
Relevant manual Type Language
FBM-M214-A CC-Link IE Field Network Waterproof Remote IO-Link Module Function Block Reference (For MELSEC-Q/L) English
FB name Function name Description Ver.
M+NZ2GF12A-60IOLH8_CCIEFIOAdv Advance setting Sets the process data size and operation of each channel. 1.00A
M+NZ2GF12A-60IOLH8_RdEventData Event data read Reads the event data of the specified channel. 1.00A
M+NZ2GF12A-60IOLH8_RdIdtData Gateway identification data read Reads the gateway identification data of the waterproof type remote IO-Link module. 1.00A
M+NZ2GF12A-60IOLH8_RdInitOprSet Initial operation setting read Reads the initial operation setting of the waterproof type remote IO-Link module. 1.00A
M+NZ2GF12A-60IOLH8_RdISDUData ISDU data read Reads the ISDU data of the specified channel. 1.00A
M+NZ2GF12A-60IOLH8_RdStrData Storage data read Reads the storage data of the specified channel. 1.00A
M+NZ2GF12A-60IOLH8_WtDataStrSet Data storage setting write Writes the data storage setting to each channel. 1.00A
M+NZ2GF12A-60IOLH8_WtInitOprSet Initial operation setting write Writes the initial operation setting to the waterproof type remote IO-Link module. 1.00A
M+NZ2GF12A-60IOLH8_WtISDUData ISDU data write Writes the ISDU data to the specified channel. 1.00A
M+NZ2GF12A-60IOLH8_WtDeviceValid Device verification setting write Sets the device verification of the specified channel. 1.00A


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (English): Version 1.09K or later


[Installation method]

  1. Execute setup.exe in the fb-nz2gf12a-60iolh8_v100a_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.