This FB library is for the CC-Link IE Field Network high-speed counter module.
| Applicable model | NZ2GFCF-D62PD2 |
|---|
| File name | Size | Last update | Version |
|---|---|---|---|
| fb-nz2gfd62_v100a_e.zip | 3,303,496 bytes | Jun. 14, 2013 | 1.00A |
| Relevant manual | Type | Language |
|---|---|---|
| FBM-M100-A | CC-Link IE Field Network High-Speed Counter Module FB Library Reference Manual | English |
| FBM-M108-A | Chinese (simplified) |
| FB name | Function name | Description | Ver. |
|---|---|---|---|
| M+NZ2GFD62_SetCncdOutput | Coincidence output function setting | Sets the point of the coincidence output and resets the coincidence output. | 1.00A |
| M+NZ2GFD62_Preset | Preset/replace | Executes the preset/replace of the present value. | 1.00A |
| M+NZ2GFD62_LatchCntOperation | Latch counter function operation | Executes the latch counter function. | 1.00A |
| M+NZ2GFD62_SamplingOperation | Sampling counter function operation | Executes the sampling counter function. | 1.00A |
| M+NZ2GFD62_PeriodicPlsCnt | Periodic pulse counter function operation | Executes the periodic pulse counter function. | 1.00A |
| M+NZ2GFD62_FrequencyMeas | Frequency measurement | Starts the frequency measurement function and reads the measured frequency value that has been calculated. | 1.00A |
| M+NZ2GFD62_RotationSpeedMeas | Rotation speed measurement | Starts the rotation speed measurement function and reads the measured rotation speed value that has been calculated. | 1.00A |
| M+NZ2GFD62_PulseMeas | Pulse measurement | Starts the pulse measurement function and reads the measured pulse value. | 1.00A |
| M+NZ2GFD62_PWMOutput | PWM output | Executes the PWM output function. | 1.00A |
| M+NZ2GFD62_ErrorOperation | Error operation | Monitors errors and warnings, and performs error reset. | 1.00A |
| M+NZ2GFD62_DegreeToCountVal | Angle conversion | Calculates the count value from the angle. | 1.00A |
| M+NZ2GFD62_SetCamSwitch | Cam switch setting | Performs the specified cam switch output setting. | 1.00A |
| M+NZ2GFD62_SetInitData | Initial data setting | Performs the initial data setting. | 1.00A |
[Precautions for using the file]
Install the FB library to the personal computer in which GX Works2 of the following version has been installed.
[How to extract the compressed file]
Copy the file to a folder.
After the copied file is decompressed, the fb-nz2gfd62_v100a_e folder is created.
Decompression method 1): For the OS with the ZIP-compatible decompression function
Decompression method 2): For the OS without the ZIP-compatible decompression function
* Use the decompression tool at users' own risk.
[Installation method]
[How to use MELSOFT Library]
[Precautions for using MELSOFT Library]