MELSOFT Library

FB for the analog-digital converter module (other languages)

This FB library is for the MELSEC-Q high speed analog-digital converter module.

Applicable model Q64ADH
File name Size Last update Version
fb-q64adh_v100a_e.zip 2,816,921 bytes May 18, 2012 1.00A
Relevant manual Type Language
FBM-M086-A MELSEC-Q High Speed Analog-Digital Converter Module FB Library Reference Manual English
FB name Function name Description Ver.
M+Q64ADH_ReadADVal Read A/D conversion data Reads the A/D conversion data of a specified channel. 1.00A
M+Q64ADH_ReadAllADVal Read all A/D conversion data Reads the A/D conversion data of all channels. 1.00A
M+Q64ADH_ReadOperationVal Read digital operation value Reads the digital operation value of a specified channel. 1.00A
M+Q64ADH_ReadAllOperationVal Read all digital operation values Reads the digital operation values of all channels. 1.00A
M+Q64ADH_SetConvertSpeed Conversion speed setting Sets the conversion speed. 1.00A
M+Q64ADH_SetADConversion Enable/disable A/D conversion Enables or disables A/D conversion for a specified channel or all channels. 1.00A
M+Q64ADH_SetAverage Averaging process setting Configures averaging processing settings of a specified channel. 1.00A
M+Q64ADH_SetScaling Scaling setting Configures scaling settings of a specified channel. 1.00A
M+Q64ADH_SetProcessAlarm Process alarm setting Configures process alarm settings of a specified channel. 1.00A
M+Q64ADH_SetInputSignalErr Input signal error detection setting Configures input signal error detection settings of a specified channel. 1.00A
M+Q64ADH_RequestSetting Operation condition setting request Applies changes made to each function's settings. 1.00A
M+Q64ADH_SetOffsetVal Offset setting Sets the offset value of a specified channel to the current analog value. 1.00A
M+Q64ADH_SetGainVal Gain setting Sets the gain value of a specified channel to the current analog value. 1.00A
M+Q64ADH_SetShift Shift setting Performs the shift setting of a specified channel. 1.00A
M+Q64ADH_ErrorOperation Error operation Performs monitoring and reset of error codes. 1.00A
M+Q64ADH_SetDigitalClip Digital clipping setting Enables or disables the digital clipping of a specified channel. 1.00A
M+Q64ADH_SetLoggingPARAM Logging function parameter setting Performs the logging function of a specified channel. 1.00A
M+Q64ADH_SaveLogging Logging data save Saves the logging data of a specified channel in a file. 1.00A
M+Q64ADH_SetFlowRatePARAM Flow amount integration function parameter setting Sets the flow amount integration function of a specified channel. 1.00A
M+Q64ADH_MakeFlowRateDailyReport Flow amount daily report creation Saves the flow amount daily report data of all channels in a file. 1.00A


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (English): Version 1.24A or later
  2. GX Works2 (Chinese (simplified)): Version 1.49B or later


[How to extract the compressed file]

Copy the file to a folder.
After the copied file is decompressed, the fb-q64adh_v100a_e folder is created.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Installation method]

  1. Execute setup.exe in the fb-q64adh_v100a_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.