This FB library is for the MELSEC-Q current transformer input module.
| Applicable model | Q68CT |
|---|
| File name | Size | Last update | Version |
|---|---|---|---|
| fb-q68ct_v100a_e.zip | 3,357,635 bytes | May 18, 2012 | 1.00A |
| Relevant manual | Type | Language |
|---|---|---|
| FBM-M085-A | MELSEC-Q Current Transformer Input Module FB Library Reference Manual | English |
| FB name | Function name | Description | Ver. |
|---|---|---|---|
| M+Q68CT_ReadDigitalVal | Read digital output value, dropout status | Reads the digital output value and dropout status of a specified channel. | 1.00A |
| M+Q68CT_ReadAllDigitalVal | Read all digital output values, dropout status | Reads the digital output values and dropout status of all specified channels. | 1.00A |
| M+Q68CT_ReadScalingVal | Read scaling value | Reads the scaling value of a specified channel. | 1.00A |
| M+Q68CT_ReadAllScalingVal | Read all scaling values | Reads the scaling values of all channels. | 1.00A |
| M+Q68CT_ReadPeakCurrentData | Read peak current detection data | Reads the peak current detection data (peak current detection flag and peak current detection count) of a specified channel. | 1.00A |
| M+Q68CT_SetSamplingPeriod | Sampling cycle setting | Sets the sampling cycle. | 1.00A |
| M+Q68CT_SetConversion | Enable/disable conversion | Enables or disables conversion for a specified channel or all channels. | 1.00A |
| M+Q68CT_SetAverage | Averaging process setting | Performs averaging process for a specified channel. | 1.00A |
| M+Q68CT_SetScaling | Scaling setting | Configures scaling setting of a specified channel. | 1.00A |
| M+Q68CT_SetProcessAlarm | Process alarm setting | Configures process alarm settings of a specified channel. | 1.00A |
| M+Q68CT_SetRateAlarm | Rate alarm setting | Configures rate alarm setting of a specified channel. | 1.00A |
| M+Q68CT_SetInputSignalErr | Input signal error detection setting | Configures input signal error detection settings of a specified channel. | 1.00A |
| M+Q68CT_SetDropout | Dropout setting | Configures dropout setting of a specified channel. | 1.00A |
| M+Q68CT_SetPeakCurrentData | Peak current detection setting | Configures peak current detection setting of a specified channel. | 1.00A |
| M+Q68CT_RequestSetting | Operation condition setting request | Applies changes made to each function's settings. | 1.00A |
| M+Q68CT_SetOffsetVal | Offset setting | Sets the offset value of a specified channel. | 1.00A |
| M+Q68CT_SetGainVal | Gain setting | Sets the gain value of a specified channel. | 1.00A |
| M+Q68CT_ErrorOperation | Error operation | Performs monitoring of error codes and error reset. | 1.00A |
| M+Q68CT_SetLoggingPARAM | Logging function parameter setting | Performs the logging function of a specified channel. | 1.00A |
| M+Q68CT_SaveLogging | Logging data save | Saves the logging data of a specified channel in a CSV file. | 1.00A |
[Precautions for using the file]
Install the FB library to the personal computer in which GX Works2 of the following version has been installed.
[How to extract the compressed file]
Copy the file to a folder.
After the copied file is decompressed, the fb-q68ct_v100a_e folder is created.
Decompression method 1): For the OS with the ZIP-compatible decompression function
Decompression method 2): For the OS without the ZIP-compatible decompression function
* Use the decompression tool at users' own risk.
[Installation method]