MELSOFT Library

FB for the current transformer input module (other languages)

This FB library is for the MELSEC-Q current transformer input module.

Applicable model Q68CT
File name Size Last update Version
fb-q68ct_v100a_e.zip 3,357,635 bytes May 18, 2012 1.00A
Relevant manual Type Language
FBM-M085-A MELSEC-Q Current Transformer Input Module FB Library Reference Manual English
FB name Function name Description Ver.
M+Q68CT_ReadDigitalVal Read digital output value, dropout status Reads the digital output value and dropout status of a specified channel. 1.00A
M+Q68CT_ReadAllDigitalVal Read all digital output values, dropout status Reads the digital output values and dropout status of all specified channels. 1.00A
M+Q68CT_ReadScalingVal Read scaling value Reads the scaling value of a specified channel. 1.00A
M+Q68CT_ReadAllScalingVal Read all scaling values Reads the scaling values of all channels. 1.00A
M+Q68CT_ReadPeakCurrentData Read peak current detection data Reads the peak current detection data (peak current detection flag and peak current detection count) of a specified channel. 1.00A
M+Q68CT_SetSamplingPeriod Sampling cycle setting Sets the sampling cycle. 1.00A
M+Q68CT_SetConversion Enable/disable conversion Enables or disables conversion for a specified channel or all channels. 1.00A
M+Q68CT_SetAverage Averaging process setting Performs averaging process for a specified channel. 1.00A
M+Q68CT_SetScaling Scaling setting Configures scaling setting of a specified channel. 1.00A
M+Q68CT_SetProcessAlarm Process alarm setting Configures process alarm settings of a specified channel. 1.00A
M+Q68CT_SetRateAlarm Rate alarm setting Configures rate alarm setting of a specified channel. 1.00A
M+Q68CT_SetInputSignalErr Input signal error detection setting Configures input signal error detection settings of a specified channel. 1.00A
M+Q68CT_SetDropout Dropout setting Configures dropout setting of a specified channel. 1.00A
M+Q68CT_SetPeakCurrentData Peak current detection setting Configures peak current detection setting of a specified channel. 1.00A
M+Q68CT_RequestSetting Operation condition setting request Applies changes made to each function's settings. 1.00A
M+Q68CT_SetOffsetVal Offset setting Sets the offset value of a specified channel. 1.00A
M+Q68CT_SetGainVal Gain setting Sets the gain value of a specified channel. 1.00A
M+Q68CT_ErrorOperation Error operation Performs monitoring of error codes and error reset. 1.00A
M+Q68CT_SetLoggingPARAM Logging function parameter setting Performs the logging function of a specified channel. 1.00A
M+Q68CT_SaveLogging Logging data save Saves the logging data of a specified channel in a CSV file. 1.00A


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (English): Version 1.24A or later
  2. GX Works2 (Chinese (simplified)): Version 1.49B or later


[How to extract the compressed file]

Copy the file to a folder.
After the copied file is decompressed, the fb-q68ct_v100a_e folder is created.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Installation method]

  1. Execute setup.exe in the fb-q68ct_v100a_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.