MELSOFT Library

FB for the positioning modules (other languages)

This FB library is for the MELSEC-Q positioning module.

Applicable model QD73A1
File name Size Last update Version
fb-qd73a1_v100a_e.zip 2,293,042 bytes Dec. 27, 2012 1.00A
Relevant manual Type Language
FBM-M088-A MELSEC-Q QD73A1 Positioning Module FB Library Reference Manual English
FB name Function name Description Ver.
M+QD73A1_SetFPARAM Fixed parameter setting Sets fixed parameters (Pr.1 to Pr.4). 1.00A
M+QD73A1_SetVPARAM Variable parameter setting Sets variable parameters (Pr.5 to Pr.9). 1.00A
M+QD73A1_SetZData OPR data setting Sets OPR parameters (Pr.10 to Pr.13). 1.00A
M+QD73A1_SetPosiData Positioning data setting Sets positioning data (Da.1 to Da.5). 1.00A
M+QD73A1_CPUReady PLC READY signal ON Outputs the PLC READY signal. 1.00A
M+QD73A1_StartPosi Positioning start Starts positioning. 1.00A
M+QD73A1_JOG JOG start Starts JOG. 1.00A
M+QD73A1_StartFeed Fixed-feed start Starts fixed-feed. 1.00A
M+QD73A1_ChgCurrentVal Current value change Changes the current value. 1.00A
M+QD73A1_ChgSpeed Speed change Changes the speed. 1.00A
M+QD73A1_VPChgDistance Speed-position movement amount change Changes the speed-position movement amount. 1.00A
M+QD73A1_VPRestart Speed-position mode restart Restarts the control in the speed-position control switch mode. 1.00A
M+QD73A1_ClearErrorCounter Deviation counter clear Clears the deviation counter. 1.00A
M+QD73A1_ErrorOperation Error operation Monitors errors and resets errors. 1.00A
M+QD73A1_SetZeroVal Zero setting Sets the zero setting for the analog output value. 1.00A
M+QD73A1_SetGainVal Gain setting Sets the gain setting for the analog output value. 1.00A


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (English): Version 1.24A or later
  2. GX Works2 (Chinese (simplified)): Version 1.49B or later


[How to extract the compressed file]

Copy the file to a folder.
After the copied file is decompressed, the fb-qd73a1_v100a_e folder is created.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Installation method]

  1. Execute setup.exe in the fb-qd73a1_v100a_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.