MELSOFT Library

FB for the temperature control module (other languages)

This FB library is for the MELSEC-Q/L temperature control module.

Applicable model Q64TCTT, Q64TCTTBW, Q64TCRT, Q64TCRTBW, Q64TCTTN, Q64TCTTBWN, Q64TCRTN, Q64TCRTBWN
L60TCTT4, L60TCTT4BW, L60TCRT4, L60TCRT4BW
File name Size Last update Version
fb-tc4_v110l_e.zip 8,269,590 bytes Jun. 30, 2017 1.10L
Relevant manual Type Language
FBM-M064-C MELSEC-Q/L Temperature Control Module FB Library Reference Manual English
FBM-M084-C Chinese (simplified)
FB name Function name Description Ver.
M+TC4_SetBPARAM Basic settings Sets the basic settings. 1.00A
M+TC4_SetCNTBPARAM Control basic parameters setting Sets the control basic parameters setting. 1.00A
M+TC4_SetCNTDPARAM Control detailed parameters setting Sets the control detailed parameters setting. 1.00A
M+TC4_SetAlertsFunction Alert function setting Sets the alert function setting. 1.00A
M+TC4_SetOtherSettings Other settings Sets the other settings. 1.00A
M+TC4_SetConversion Conversion enable/disable setting Sets the conversion enable/disable setting. 1.00A
M+TC4_SetProcessAlarm Process alarm setting Sets the process alarm setting. 1.00A
M+TC4_SetRateAlarm Rate alarm setting Sets the rate alarm. 1.00A
M+TC4_SetPVScaling Process value (PV) scaling function setting Sets the process value (PV) scaling function. 1.00A
M+TC4_MoniCJTemperature Cold junction temperature process value monitoring function Sets the cold junction temperature compensation and reads the cold junction temperature process value. 1.00A
M+TC4_Autotuning Auto tuning Sets and executes auto tuning. 1.00A
M+TC4_Selftuning Self tuning Sets the self tuning setting and monitors the self tuning flag. 1.00A
M+TC4_PIDControl PID control Reads the PID constants and executes a forced PID control stop. 1.00A
M+TC4_HeaterDisconnection Heater disconnection detection function Sets the heater disconnection detection and monitors the heater disconnection. 1.00A
M+TC4_LoopDisconnection Loop disconnection detection function Sets the loop disconnection detection and monitors the loop disconnection. 1.00A
M+TC4_SimultaneousTemperature Simultaneous temperature rise function Sets simultaneous temperature rise function setting and monitors the status of the simultaneous temperature rise. 1.00A
M+TC4_SetPeakCurrentSuppress Peak current limit control setting Sets the peak current limit control setting. 1.00A
M+TC4_AlertStatus Alert status check Monitors an alert that has occurred. 1.00A
M+TC4_ErrorOperation Error operation Monitors an error code and performs an error reset. 1.00A
M+TC4_ReadVal Value read Reads the values to the specified devices. 1.00A
M+TC4_ParamBackup Setting value backup Backs up the setting value or executes the default setting registration command. 1.00A
M+TC4_SetPVAverage Process value (PV) moving averaging process setting Sets the number of moving averaging of the moving averaging process function for the temperature process value (PV). 1.00A


[Improvement history of the FB for the MELSEC-Q/L temperature control module from Ver.1.01B to Ver.1.10L (Jun., 2017)]

No. Description
1 The applicable version of GX Works2 has been added.
・This FB can be installed to GX Works2 of any language version.


[Precautions for using the file]

Install the FB library to the personal computer in which GX Works2 of the following version has been installed.

  1. GX Works2 (Japanese): Version 1.86Q or later
  2. GX Works2 (English): Version 1.24A or later
  3. GX Works2 (Chinese (simplified)): Version 1.49B or later
  4. GX Works2 (Chinese (traditional)): Version 1.49B or later
  5. GX Works2 (Korean): Version 1.49B or later


[Installation method]

  1. Execute setup.exe in the fb-tc4_v110l_e folder.
  2. Install the FB library following the messages of the installer.


[How to use MELSOFT Library]

  1. Select [Library] - [Install...] from the [Project] menu.
  2. In the [Import Library to Project] dialog box, select the installed library and necessary FBs, and click the [OK] button.
  3. Paste the FB from the [Element Selection] window to the program.


[Precautions for using MELSOFT Library]

  1. Before applying the FB library of MELSOFT Library to a system, check sufficiently if no problem occurs in the control of the system.