MELSOFT Library

Program examples given in the FX3U-16CCL-M user's manual (English version)

Remarks

  • When using this sample ladder for a model which is not applicable to the provided project, change the programmable controller type with an engineering tool.
  • When using a GX Developer project for an FX3S-series module, refer to "HIME-T-P-0118A Limitations and precautions when using FX3S Series with GX Developer".
  • The provided project does not guarantee the operations on the customer's equipment. Check the settings such as device assignments and parameters according to the specifications on the customer's equipment before using the project.
Applicable model FX3U-16CCL-M
Engineering tool File name Size Last update Version
GX Works2 gw_ld-fx3_16cclm_ex_v100a_e.zip 3,763,988 bytes Nov. 30, 2016 1.00A
GX Developer gd_ld-fx3_16cclm_ex_v100a_e.zip 432,898 bytes Nov. 30, 2016 1.00A
Relevant manual Type
JY997D71701-A List of Projects with Program Examples given in MELSEC-F FX3 Series Manual
JY997D43601-D FX3U-16CCL-M USER'S MANUAL
Project name Function name Description Ver.
01_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote I/O station 1.00A
02_LD-FX3U_16CCLM_Ex_V100A Communication with the remote I/O station Example of communication between the master station and the remote I/O station 1.00A
03_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote device station 1.00A
04_LD-FX3U_16CCLM_Ex_V100A Communication with the remote device station Example of communication between the master station and the remote device station (When Remote Net Ver. 1 Mode is used) 1.00A
05_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote device station 1.00A
06_LD-FX3U_16CCLM_Ex_V100A Communication with the remote device station Example of communication between the master station and the remote device station (When Remote Net Ver. 2 Mode is used) 1.00A
07_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote device station 1.00A
08_LD-FX3U_16CCLM_Ex_V100A Communication with the remote device station Example of communication between the master station and the remote device station (When Remote Net Additional Mode is used) 1.00A
09_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the intelligent device station 1.00A
10_LD-FX3U_16CCLM_Ex_V100A Communication with the intelligent device station Example of communication between the master station and the intelligent device station (When Remote Net Ver. 1 Mode is used) 1.00A
11_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the intelligent device station 1.00A
12_LD-FX3U_16CCLM_Ex_V100A Communication with the intelligent device station Example of communication between the master station and the intelligent device station (When Remote Net Ver. 2 Mode is used) 1.00A
13_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the intelligent device station 1.00A
14_LD-FX3U_16CCLM_Ex_V100A Communication with the intelligent device station Example of communication between the master station and the intelligent device station (When Remote Net Additional Mode is used) 1.00A
15_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote I/O station, remote device station, and intelligent device station/td> 1.00A
16_LD-FX3U_16CCLM_Ex_V100A Communication in compound system Example of communication in compound system (When Remote Net Ver. 1 Mode is used) 1.00A
17_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote I/O station, remote device station, and intelligent device station 1.00A
18_LD-FX3U_16CCLM_Ex_V100A Communication in compound system Example of communication in compound system (When Remote Net Ver. 2 Mode is used) 1.00A
19_LD-FX3U_16CCLM_Ex_V100A Parameter setting Program example of parameter setup to perform a data link with the remote I/O station, remote device station, and intelligent device station 1.00A
20_LD-FX3U_16CCLM_Ex_V100A Communication in compound system Example of communication in compound system (When Remote Net Additional Mode is used) 1.00A


[How to extract the compressed file]

Copy the file to a folder.
The file is a compressed file in ZIP format.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Precautions for using the sample ladder]

  1. Before applying the sample ladder to a system, check sufficiently if no problem occurs in the control of the system.