MELSOFT Library

Program examples given in the user's manual - Analog control edition (Analog input) (English version)

Remarks

  • When using this sample ladder for a model which is not applicable to the provided project, change the programmable controller type with an engineering tool.
  • When using a GX Developer project for an FX3S-series module, refer to "HIME-T-P-0118A Limitations and precautions when using FX3S Series with GX Developer".
  • The provided project does not guarantee the operations on the customer's equipment. Check the settings such as device assignments and parameters according to the specifications on the customer's equipment before using the project.
Applicable model FX3U-4AD,FX3U-4AD-ADP,FX3G-2AD-BD
Engineering tool File name Size Last update Version
GX Works2 gw_ld-fx3_ad_ex_v100a_e.zip 1,442,199 bytes Nov. 30, 2016 1.00A
GX Developer gd_ld-fx3_ad_ex_v100a_e.zip 277,491 bytes Nov. 30, 2016 1.00A
Relevant manual Type
JY997D71701-A List of Projects with Program Examples given in MELSEC-F FX3 Series Manual
JY997D16701-P FX3S/FX3G/FX3GC/FX3U/FX3UC SERIES USER'S MANUAL - Analog Control Edition
Project name Function name Description Ver.
01_LD-FX3U_4AD_Ex_V100A Convenient function Program example using the upper and lower limit detection function, upper and lower error status automatic transfer function, scale over status automatic transfer function, and error status automatic transfer function for FX3U-4AD 1.00A
02_LD-FX3U_4AD_Ex_V100A Data history function Reads out history of one hundred times of data for all channels for FX3U-4AD to the data register. 1.00A
03_LD-FX3U_4ADADP_Ex_V100A Reading analog conversion data Basic program example to read out analog conversion (A/D conversion) data for FX3U-4AD-ADP 1.00A
04_LD-FX3U_4ADADP_Ex_V100A Changing voltage input characteristics Example for changing of voltage input characteristics for FX3U-4AD-ADP (For FX3U and FX3UC Series PLC) 1.00A
05_LD-FX3G_4ADADP_Ex_V100A Changing voltage input characteristics Example for changing of voltage input characteristics for FX3U-4AD-ADP (For FX3G and FX3GC Series PLC) 1.00A
06_LD-FX3G_2ADBD_Ex_V100A Reading analog conversion data Basic program example to read out analog conversion (A/D conversion) data for FX3G-2AD-BD 1.00A
07_LD-FX3G_2ADBD_Ex_V100A Changing voltage input characteristics Example for changing of voltage input characteristics for FX3G-2AD-BD 1.00A


[How to extract the compressed file]

Copy the file to a folder.
The file is a compressed file in ZIP format.

Decompression method 1): For the OS with the ZIP-compatible decompression function

  1. Right-click the copied file.
  2. Select "Extract All...".
    When "Extract All..." is not displayed, follow the decompression method 2).
  3. Specify the location of the extracted file, and click the "Extract" button to start the decompression.

Decompression method 2): For the OS without the ZIP-compatible decompression function

  1. If not having the ZIP-compatible decompression tool, acquire the decompressing tool.
  2. Decompress the file using the decompression tool.

* Use the decompression tool at users' own risk.


[Precautions for using the sample ladder]

  1. Before applying the sample ladder to a system, check sufficiently if no problem occurs in the control of the system.