This sample ladder is for the MELSEC-L temperature control module.
| Applicable model | L60TCTT4, L60TCTT4BW, L60TCRT4, L60TCRT4BW |
|---|
| Engineering tool | File name | Project name | Size | Last update | Version |
|---|---|---|---|---|---|
| GX Works2 | gw_ld-l60tc4_v100a_e.zip | LD-L60TC4_PRM1_V100A_E LD-L60TC4_PRM2_V100A_E LD-L60TC4_PRM3_V100A_E LD-L60TC4_PRM4_V100A_E LD-L60TC4_NPM1_V100A_E LD-L60TC4_NPM2_V100A_E LD-L60TC4_NPM3_V100A_E LD-L60TC4_NPM4_V100A_E LD-L60TC4_IEF_V100A_E |
4,775,495 bytes | Feb. 2, 2012 | 1.00A |
| GX Developer | gd_ld-l60tc4_v100a_e.zip | LD-L60TC4_NPM1_V100A_E LD-L60TC4_NPM2_V100A_E LD-L60TC4_NPM3_V100A_E LD-L60TC4_NPM4_V100A_E |
3,607,676 bytes | Feb. 2, 2012 | 1.00A |
| Relevant manual | Type | Language |
|---|---|---|
| LDM-M024-A | MELSEC-L Temperature Control Module Sample Ladder Reference Manual | English |
| LDM-M032-A | Chinese (simplified) |
| Project name | Program name | Function name | Description | Ver. |
|---|---|---|---|---|
| LD-L60TC4_PRM1_V100A_E | 01RdTmp | Temperature input | Performs the temperature input using the configuration function. | 1.00A |
| LD-L60TC4_PRM2_V100A_E | 01Tuning | Tuning | Performs the auto tuning, self-tuning and error code read operations using the configuration function. | 1.00A |
| LD-L60TC4_PRM3_V100A_E | 01PekHet | Peak current suppression, simultaneous temperature rise | Performs the peak current suppression and simultaneous temperature rise using the configuration function. | 1.00A |
| LD-L60TC4_PRM4_V100A_E | 01HetCol | Heating-cooling control | Performs the heating-cooling control using the configuration function. | 1.00A |
| LD-L60TC4_NPM1_V100A_E | 01RdTmp | Temperature input | Performs the temperature input without using the configuration function. | 1.00A |
| LD-L60TC4_NPM2_V100A_E | 01Tuning | Tuning | Performs the auto tuning, self-tuning and error code read operations without using the configuration function. | 1.00A |
| LD-L60TC4_NPM3_V100A_E | 01Peak | Peak current suppression | Performs the peak current suppression without using the configuration function. | 1.00A |
| 02Heat | Simultaneous temperature rise | Performs the simultaneous temperature rise without using the configuration function. | 1.00A | |
| LD-L60TC4_NPM4_V100A_E | 01HetCol | Heating-cooling control | Performs the heating-cooling control without using the configuration function. | 1.00A |
| LD-L60TC4_IEF_V100A_E | 01RdTmp | Temperature input | Performs the temperature input using the configuration function. | 1.00A |
[How to extract the compressed file]
Copy the file to a folder.
The file is a compressed file in ZIP format.
Decompression method 1): For the OS with the ZIP-compatible decompression function
Decompression method 2): For the OS without the ZIP-compatible decompression function
* Use the decompression tool at users' own risk.
[Precautions for using the sample ladder]